Wb-Fr Standard
Fire Rated Access Door

The WB-FR Standard Fire Rated Access Door is designed for both wall and ceiling applications. For walls, this door has an Underwriters Laboratories (UL and ULC), 1-1/2 hour “B” label, with a maximum temperature rise of 250 degrees Celsius after 30 minutes for vertical wall installations. File # R10364. Warnock Hersey International; Pittsburgh, CA 1 hr rating for combustible floor/ceiling applications. Report. # WHI-495-PSH-0191. Warnock Hersey International, Pittsburgh, CA 3 Hr. rating for non-combustible floor/ceiling assembly, Report # WHI-495-PSH-0192. This door may be used in a 2-hour fire rated wall assembly. For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (*max. size to 24” x 36”).

  • UL
  • Intertek
WB-FR
WB-FR

Features

Door and Trim

18 ga. cold rolled steel

Box Return Frame

16 ga. cold rolled steel

Insulation

2” thick mineral wool contained within door cavity

Hinge

Fully concealed rod type hinge. Allows opening to 170°.

Latch

Self-latching direct-action latch, opposite hinge. Accepts both key and knurled knob, included with each door.

Automatic Panel Closer

Standard on all doors

Inside Panel Release

Standard on all doors

Finish

White powder coat paintable finish

Masonry Anchor Straps

Standard on all doors

Options
(at extra cost)
  • Mortise lock preparation
  • Stainless steel #304 and #316 (#4 satin finish)
  • Pemko hot smoke seal gasketing
  • Custom sizes available
Ceiling Installation

To comply with current fire regulations, largest size acceptable is 24” x 36”

Dimensions

Elevation

Elevation

Section Detail

Section Detail

Model No.
Size
Hinges
Latch
Shipping Weight (lbs.)
Steel/Stainless
WB-FRS 8x8
8" x 8"
1
1
7
WB-FRS 10x10
10" x 10"
1
1
10
WB-FRS 12x12
12" x 12"
1
1
11
WB-FRS 12x18
12" x 18"
1
1
19
WB-FRS 12x24
12" x 24"
1
1
18
WB-FRS 14x14
14" x 14"
1
1
15
WB-FRS 16x16
16" x 16"
1
1
18
WB-FRS 18x18
18" x 18"
1
1
21
WB-FRS 18x24
18" x 24"
1
1
26
WB-FRS 20x20
20" x 20"
1
1
26
WB-FRS 20x30
20" x 30"
1
2
38
WB-FRS 21x36
21" x 36"
1
2
43
WB-FRS 22x22
22" x 22"
1
1
29
WB-FRS 22x24
22" x 24"
1
1
30
WB-FRS 22x30
22" x 30"
1
2
37
WB-FRS 22x36
22" x 36"
1
2
43
WB-FRS 24x24
24" x 24"
1
1
31
WB-FRS 24x30
24" x 30"
1
2
40
WB-FRS 24x36
24" x 36"
1
2
46
WB-FRS 24x48
24" x 48"
1
2
62
WB-FRS 30x30
30" x 30"
1
2
50
WB-FRS 32x32
32" x 32"
1
2
54
WB-FRS 36x36
36" x 36"
1
2
67
WB-FRS 36x48
36" x 48"
1
2
83
WB-FRS 48x48
48" x 48"
1
2
104

Size = A x B (w x h)
Rough wall opening = door size + 1/4”
Note: For fire-rated ceiling access doors, on size 16” x 16” and larger, extra spring supplied with door must be attached from back of door pan to framing or floor above. In horizontal (ceiling) applications door has self-assisted closing.